Set force next, Progr, Amming limits – Genie SILENTMAX 1000 User Manual

Page 6: Travel limits, Force control

Advertising
background image

©2011 The Genie Company

9/2011

5

WARNING

s Make sure doorway is in view and clear of obstacles and

people to avoid injury or damage to property.

s DO NOT operate this unit from wall console before LIMITS

and FORCE are set. Severe damage to the opener can occur.

s The bullet MUST be engaged to carriage BEFORE setting

limits. See Installation Poster (if provided) or call
Customer Service at 800-35-GENIE or visit
www.geniecompany.com.

NOTE: If bullet has NOT been engaged to
the carriage, do so no .

PROGR

2

Please note that there is a 30 second timeout between

each programming step.

If you see two flashing RED LEDs, you have initiated
a timeout.
In the ev

w See page 9.

CONTACT REVERSE TEST

The Force and Limit settings MUST be COMPLETED

before performing Contact Reverse Test.

1.

Test.

Place a 2" x 4"
board (laid flat)
under center of
door opening.

2. Adjustment, if needed.

s

WARNING

A moving door can cause serious injury or death.

1. Keep people clear of opening while door is moving.
2. Do

NOT allow children to play with opener, including

wall console, remote, or wireless keypad.

3. During programming, door opener could begin to run,

so stay away from moving door and its parts.

Once the Contact Revese Test is complete,
continue with programming Remotes.

or it does not reverse, it may be due to an improperly set
down limit. Repeat TRAVEL LIMITS program and Test again.
Repeat as needed until door passes test. For further help
refer to Maintenance &Troubleshooting, page 13.

ent of a timeout you must restart at beginning.

Press & hold
2 seconds or until
LEDs react. Release.

Press & hold
2 seconds or until
LEDs react. Release.

Long LED turns Blue,
Round LED OFF.

Then Long LED OFF
Round LED Flashing.

Long LED turns Blue, then flashes.

Press & hold
until door is fully
open. Then release.

Press &
Release.

DOOR LIMITS ARE SET

SET FORCE NEXT

PROGRAM

SET

FLASHING

DOOR FULLY OPEN

DOOR FULLY CLOSED

OFF

O

RED

RED

FF

Press &
Release.

PROGRAM

SET

Press &
Release the
Open/Close
button.

DOOR CLOSES.
s When door contacts board,
it must stop and reverse direction
(within 2 seconds) to the fully
open position.

OFF

OFF

AMMING LIMITS

TRAVEL LIMITS

UP LIMIT

DOWN LIMIT

Door fully closes.

Door fully opens.

FORCE CONTROL

Press &
Release
Open/Close
button.

ACTION

INDICATION/RESULT

ACTION

INDICATION/RESULT

Press &
Release
Open/Close
button.

ON WALL CONSOLE

Press &
Release the
Open/Close
button.

FORCE CONTROL IS SET

1

2

1

2

1

3

4

5

6

2

3

DOOR OPENS.

ACTION

LED INDICATION/RESULT

OFF

OFF

ON

BLUE

BOTH FLASH BLUE

FLASHING

Press & hold
until door is fully
closed. Then release.

B

During the initial setting
of the limits- the LEDs will
turn to RED—NOT OFF

oth BLUE then LEDs Off confirms limit set.

OFF

OFF

BOTH FLASH BLUE

Both BLUE then LEDs Off confirms limit set.

Advertising