Save these instructions, Maintenance & troubleshooting – Genie SILENTMAX 1000 User Manual

Page 9

Advertising
background image

8

©2011 The Genie Company

9/2011

s

release handle

DOWN and let go to release door carriage assembly
from drive system.

s

s

freely and smoothly.

d

n

a

t

e

e

f

4

o

t

3

y

l

e

t

a

m

i

x

o

r

p

p

a

y

l

l

a

u

n

a

m

r

o

o

d

e

s

i

a

let go.
– Door should remain stationary or move very

slowly.

– If door moves quickly, CONTACT A TRAINED

DOOR SYSTEM TECHNICIAN.

s

(refer to page 13)

– Operate door using remote or wall console.
– Door will re-attach itself to carriage assembly.

Check that both the RED and GREEN LEDs are ON steady.
This indicates the system is working properly. If both LEDs
are not ON steady, check the appropriate items below.

If the system appears to be working properly, perform the
check as follows:
1. Start the door closing.
2. Pass on object through the beam, the door should
stop and reverse to the fully open position.

Perform the check as follows:

DOOR BALANCE (SPRING TENSION)

Safe-T-Beam® (STB) SYSTEM CHECK

s

– Check for obstruction.
– Check alignment.
– Verify wire routing from STBs to STB connection

in powerhead.

– Check for signal interference

Safe-T-Beam® unit (For multiple door installations).

from another.

s

– Check wiring and wire connections.

MAINTENANCE & TROUBLESHOOTING

3

If you have any questions, please do not hesitate to

contact customer service at: 1-800-35-GENIE or visit

IMPORTANT SAFETY

INSTRUCTIONS

WARNING:

To reduce the risk

of severe injury or death

1. READ AND FOLLOW ALL INSTRUCTIONS.
2.
Never let children operate or play with the door controls.

Keep the remote away from children.

3. Always keep the moving door in sight and away from people

and objects until the door is completely closed. NO ONE

.

R

O

O

D

G

N

I

V

O

M

E

H

T

F

O

H

T

A

P

E

H

T

S

S

O

R

C

D

L

U

O

H

S

4. NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.
5. Test opener monthly. The door MUST reverse on contact

with a 1-1/2" high object (or a 2" x 4" board laid flat) at the

center of the doorway on the floor. After adjusting either the

force or the limit of travel, retest the door opener. Failure to
adjust the opener properly may cause severe injury or death.

6. When possible, use the emergency release only when the

door is closed. Use caution when using this release

door open

with the

. Weak or broken springs are capable of increasing

the rate of door closure and increasing the risk of severe
injury or death.

7. KEEP DOORS PROPERLY BALANCED. See your garage door

Owner’s Manual. An improperly balanced door increases the

risk of severe injury or death. Have a trained door system

technician make repairs to cables, spring assemblies, and
other hardware.

8.

SAVE THESE INSTRUCTIONS.

www.geniecompany.com.

WARNING

s

,

s

t

e

k

c

a

r

b

,

s

e

l

b

a

c

,

s

g

n

i

r

p

s

(

e

r

a

w

d

r

a

h

r

o

o

d

e

g

a

r

a

G

pulleys, etc.) are under extreme pressure and
tension.

s

DO NOT attempt to repair or adjust door springs or

any hardware, and DO NOT OPERATE garage door

automatically or manually if door is improperly

balanced or springs are broken.

CONTACT A TRAINED DOOR SYSTEM TECHNICIAN.

ROUTINE MONTHLY MAINTENANCE

Basic monthly maintenance tasks.

s Safe-T-Beam® System Check

s Door balan

s Lubricate Door Hardware

ce

s Contact reverse

WARNING

Use wall console supplied with opener. Other approved wall
consoles may be available. Unapproved or incompatible wall

consoles can cause the opener to operate unexpectedly.

CONTACT REVERSE

See page 5.

TEST

s

LUBRICATE DOOR HARDWARE

Lubricate door rollers, bearings and hinges:

Advertising