Remote Network Monitoring 57

Alarm Group Configuration

Alarm Group Index
• creation

Create a new alarm group (number).

• modification & deletion Select an existing alarm group to monitor or edit.

Variable Category

RMON/ rptr group/ rptr port

Alarm Index

The current alarm group index number

Alarm Variable Category

Read only

Alarm Interval

The time in seconds over which the data is sampled.

Alarm Sample Type
• Absolute

Value stored is compared to the threshold level

• Delta

Value stored is compared to the difference between
the variable at the last sampling and its current
value.

Alarm Value

Value of the statistic during the last sampling period.

Alarm Startup

No Change/Rising Alarm/Falling Alarm/Both Alarms

Alarm Rising Threshold

Threshold for the sampled statistic. When the current
sampled value is greater than or equal to this
threshold, and the value of this sample at the last
sampling interval was less than the threshold, then a
single event is generated. After a rising event is
generated, another rising event is not generated until
the sampled value falls below this threshold and
reaches the Alarm Falling Threshold.

Alarm Falling Threshold

Threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold,
and the value of this sample at the last sampling
interval was greater than the threshold, then a single
event is generated. After a falling event is generated,
another falling event is not generated until the
sampled value rises above this threshold and
reaches the Alarm Rising Threshold.

Alarm Rising Event

Index of the event entry that is used when the

Index

Rising Threshold is crossed.

Alarm Falling Event

Index of the event entry that is used when the

Index

Rising Threshold is crossed.

Alarm Owner

The entity that configured this entry and is using
the resources assigned to it.

Alarm Status

Valid/underCreation/invalid