OWNER’S MANUAL

Nozzle

(35,000 Btu/Hr Model)

1.

Remove upper shell (see page 8).

2.

Remove fan (see page 13).

3.

Remove fuel and air line hoses from
nozzle assembly.

4.

Turn nozzle assembly 1/4 turn to left
and pull toward motor to remove.

5.

Place plastic hex-body into vise and
lightly tighten.

6.

Carefully remove nozzle from the
nozzle adapter using 5/8" socket
wrench.

7.

Blow compressed air thru face of nozzle.
This will free any dirt in nozzle area.

8.

Inspect nozzle seal for damage.

9.

Replace nozzle into nozzle adapter un-
til nozzle seats. Tighten 1/3 turn more
using 5/8" socket wrench (4.5-5.1 n-m/
40-45 inch-pounds).

10. Attach nozzle assembly to burner strap.

11. Attach fuel and airline hoses to nozzle

assembly.

12. Replace fan (see page 13).

13. Replace fan guard and upper shell.

Combustion
Chamber

Fuel Line
Hose

Air Line Hose

Figure 20 - Removing Air and Fuel Line
Hoses, 35,000 Btu/Hr Model

Nozzle
Assembly

Burner
Strap

Figure 21 - Removing Nozzle Assembly,
35,000 Btu/Hr Model

Figure 22 - Nozzle and Nozzle Adapter,
35,000 Btu/Hr Model

Air line Fitting

Fuel line Fitting

Nozzle

Nozzle Seal

Nozzle
Adapter

Nozzle
Assembly

Nozzle
Face

SERVICE
PROCEDURES

Continued

Nozzle

(70/100/150,000 Btu/Hr Models)

1.

Remove upper shell (see page 8).

2.

Remove fan (see page 13).

3.

Remove fuel and air line hoses from
burner head.

4.

Remove spark plug wire from spark plug.

5.

Remove spark plug from burner head
using 13/16" open-end wrench.

6.

Remove three screws using 5/16" nut-
driver and remove burner head from
combustion chamber.

7.

Place burner head into vise and lightly
tighten.

8.

Carefully remove nozzle from burner
head using 5/8" socket wrench (see Fig-
ure 24).

9.

Blow compressed air thru face of nozzle.
This will free any dirt in nozzle area.

10. Inspect nozzle seal for damage.

Figure 23 - Removing Burner Head,
70/100/150,000 Btu/Hr Models

Spark
Plug

Combustion
Chamber

Burner
Head

Air Line Hose

Fuel Line Hose

Screw

Spark Plug
Wire

Figure 24 - Removing Nozzle, 70/100/
150,000 Btu/Hr Models

Nozzle
Face

Nozzle

Burner
Head

Air line
Fitting

Fuel line
Fitting

Nozzle
Seal

11. Replace nozzle into burner head and

tighten firmly (9.1-12.4 n-m/80-110
inch-pounds).

12. Attach burner head to combustion

chamber.

13. Install spark plug in burner head.

14. Attach spark plug wire to spark plug.

15. Attach fuel and airline hoses to burner head.

16. Replace fan (see page 13).

17. Replace fan guard and upper shell.