4

104468

PORTABLE FORCED AIR HEATERS

R

FUELS

Do not use heavy fuels such as No. 2 fuel oil
or No. 2 Diesel. Using heavy fuels will
result in:

• clogged fuel filter and nozzle

• carbon build up on spark plug

• use of non-toxic anti-icer in fuel during

very cold weather

IMPORTANT: Use a KEROSENE ONLY
container. Be sure storage container is clean.
Foreign matter such as rust, dirt, or water
will cause the flame-out control to shut
down heater. Foreign matter may also re-
quire you to clean fuel system often.

WARNING: Use only kerosene

or No. 1 fuel oil to avoid risk of fire
or explosion. Never use gaso-
line, naphtha, paint thinners, al-
cohol or other highly flammable
fuels.

ASSEMBLY

(FOR 100,000 AND 150,000
BTU/HR MODELS ONLY)

These models are furnished with wheels and
handles. Wheels, handles, and the mounting
hardware are found in the shipping carton.

Tools Needed

• Medium Phillips Screwdriver

• 3/8" Open or Adjustable Wrench

• Hammer

1.

Slide axle through wheel support
frame. Install wheels on axle.

IMPORTANT: When installing
wheels, point extended hub of wheels
toward wheel support frame (see Fig-
ure 3).

Figure 3 - Wheel and Handle Assembly, 100/150,000 Btu/Hr Models Only

Screw

Wheel
Support
Frame

Wheel

Cap Nut

Nut

Extended
Hub

Front Handle

Axle

Rear
Handle

Air
Inlet

Fuel Tank
Flange

Hot Air
Outlet

2.

Place cap nuts on axle ends. Gently tap
with hammer to secure.

3.

Place heater on wheel support frame.
Make sure air inlet end (rear) of heater
is over wheels. Line up holes on fuel
tank flange with holes on wheel sup-
port frame.

4.

Place front handle and rear handle on
top of fuel tank flange. Insert screws
through handles, fuel tank flange, and
wheel support frame. Attach nut finger
tight after each screw is inserted.

5.

After all screws are inserted, tighten
nuts firmly.

VENTILATION

Provide a fresh air opening of at least 2800
square cm (three square feet) for each
100,000 Btu/Hr rating. Provide extra fresh
air if more heaters are being used.

Example: A 150,000 Btu/Hr heater re-
quires one of the following:

• a 4.88 m (16 foot) wide two-car garage

door raised 8.59 cm (3.38 inches)

• a 2.75 m (9 foot) wide single-car garage

door raised 15.24 cm (six inches)

• two, 76.2 cm (thirty-inch) windows

raised 30.48 cm (twelve inches)

WARNING: Follow the mini-

mum fresh, outside air ventila-
tion requirements. If proper fresh,
outside air ventilation is not pro-
vided, carbon monoxide poison-
ing can occur. Provide proper
fresh, outside air ventilation be-
fore running heater.

Advertising