Phone Number Programming

You can program up to 6 Emergency Phone Numbers. When the system is in panic,
the control panel will call these phone numbers and announce its status.

The 6 emergency phone numbers include:
- 5 voice message phone numbers
- 1 Contact ID message phone number

Program the following for Voice Message Phone Numbers
- Phone memory (from 1 to 5), this is where the phone numbers will be stored
- Phone number, up to 29 digits.
- Redial count, this is how many times that phone number will be called, from 1
to 9 times.
- Repeat count, this is how many times the emergency message will be repeated,
from 1 to 9 times.

**Note:
You may enter a 3-second pause between digits by pressing [Mute] if needed.
You may also enter consecutive multiple pause periods. For example, you may
enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number
(123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be
a password to a paging system, or an access code for a phone dialing system.

10

INSTALLATION

You will hear [Enter
Redial]
.

You will hear [Enter
Repeat]
.

3 beeps for valid

password. 1 long beep
for invalid password.

During emergency, phone

memory 1 will be called first,
then phone memory 2, 3, 4, and
5. So phone memory 1 has
higher priority.

You will hear [Enter
phone memory]
.

You will hear [Phone
Accepted]
indicating the
phone number and its
settings have been
programmed successfully.

Repeat is the number of times
that voice emergency message
will be played, from 1 to 9 times.
It is recommended to set up
the repeat time to 5 or more.

Redial is the number of times
that phone number will be
called. Each phone number
can have a different redial
count, from 1 to 9 times.

Phone number can be up to 29
digits.**

Enter master password to
programming mode

[1] to [9]

+ [Arm]

[1] to [9]

+ [Arm]

[1]

[1] to [5]

[PROG]
[MPIN]

[Phone
number]
+ [Arm]

Enter Repeat

count

Enter Redial

count

Enter
Programming
mode

Select phone
number
programming

Enter phone
number

Enter phone
memory

1

2

3

4

5

6

Step

Keys

Function

Description

Note

Questions

Solutions

Why I can’t arm my system?

Make sure none of the sensors are
triggered. You can check this by the zone
LEDs, none of them should blink.

I cannot arm the system even when no

You need to disarm the system again by

sensor is triggered, and the ARM LED

either entering the password or disarm by

is off.

keychain remote. Although the ARM LED
is off, but the system is not completely
disarmed after an alarm was triggered.
Refer to page 22 on how to completely
disarm a control panel after an alarm has
been triggered.

Why the ARM LED keeps flashing?

That means you have not programmed any
emergency phone numbers. For instructions
on how to program emergency phone
numbers, please see page 10.

How do I exit programming mode

You can press the programming button on

when I’m in the middle of it?

the side of the unit to quit programming
anytime.

When a sensor is triggered, the alarm

You have programmed that sensor in alarm

sounds instantly even it is not armed,

mode, instead of beep mode. Please refer

why is that?

to page 29 for instructions of how to program
it back to beep mode.

When the alarm is triggered, why

The control panel will stop calling when it

the control panel won’t call all the

is disarmed by any one of the recipients.

programmed phone numbers? It

Disarm can also be done locally thru the

always stops before calling the

keypad on the control panel by entering a

last number.

valid password.

Why the control panel doesn’t beep

You have placed the buzzer mode selector

when a sensor is triggered, while

on the side of the control panel to “II”, this

only the zone LED flashes?

will disable the beeping. Placing it to “I” will
enable the beeping.

The control panel is in armed mode,

If the triggered sensor is programmed in the

why activating a sensor will not cause

Alert Zone (Bypass Zone), alarm will not

an alarm, or call any emergency phone

sound, and emergency call will not be made

number?

if this sensor is triggered. The control panel
will only respond when it is disarmed, in
alert mode.

TROUBLE SHOOTING