Operation, Advanced programming, Alert mode – Multi-Link ML-001 User Manual

Page 20: Erase sensors

Advertising
background image

Note:
- Each zone can program up to 2 sensors. There are 5 zones, so up to 10 sensors
can be programmed to the control panel. Please refer to page 37, "Sensor
Location Selection Guide" for detail information.

Alert Mode Examples (Door/Window sensor sold separately)

Note:
-For Door / Window sensor, alert notification (beeping and LED flashing) will
continue until the sensor is in closed position, i.e. closing the window or door.

-For motion sensor, the alert notification was disabled at the factory default. To
perform the walk test, it requires to enable the Alert Zone (Bypass Zone) feature
in the Control Panel. After the walk test, it needs to disable this alert zone feature
otherwise it will bypass the signal in the alarm mode. Please refer to the page 33,
"Alert Zone" for detail. Please refer to information.

OPERATION

The Control Panel is always in one of the 2 operating modes:

1. Alert Mode - When the system is not armed (ARM LED off), it is in alert mode.
2. Alarm Mode - When the system is armed (ARM LED on), it is in alarm mode.

The Control Panel will be in alert mode automatically if the system is not armed.
Alert mode allows users inside the premises to know what sensor is triggered.
It is intended to be used when someone stays inside the premises.

In alert mode, the control panel will give you notification of the triggered sensor(s)
by voice announcement, unique beeping and LED flashing.

1

Number of beeps

Zone of the triggered sensor

2

Number of flashes of zone LED

Sensor number of the triggered sensor

Alert Mode

18

ADVANCED PROGRAMMING

Zone 1

SENSOR 1

Button [1]

SENSOR 2

Zone 2

Zone 3

Zone 4

Zone 5

Button [2]

Button [3]

Button [4]

Button [5]

Button [6]

Button [7]

Button [8]

Button [9]

Button [0]

This row

:

Buttons for
Sensor 1

Zone LED :
Flash once

This row

:

Buttons for
Sensor 2

Zone LED :
Flash twice

Erase Sensors

Proceed to the following to erase a sensor.

1

2

3

[PROG]
[MPIN]

Enter
Programming
mode

Enter master
password to
programming mode

3 beeps for valid password.
1 long beep for invalid
password.

[9]

Select erase
remote
programming

After [9] is entered, some
zone LEDs will flash or
stay off. The zone LEDs
represent whether that zone
is occupied by any sensor.
**See Table D below.

Refer to the table
below to select the
remote location.

Select the
sensor you
would like to
erase

After you have selected the
sensor, you will hear 3 beeps
and verbal confirmation
[Zone X Sensor Y Empty
Memory
], where X and Y
are the zone and sensor
numbers you have selected.

To erase an
occupied
sensor, press
[1] to [0].

ZONE LED

DESCRIPTION

Off

Zone is not occupied by any sensor

Flashes once

This zone is occupied by sensor 1.

Flashes twice

This zone is occupied by sensor 2.

Flashes once,

This zone is occupied by sensors 1 and 2.

then twice

** Table D: Zone LED status for erasing sensors.

Step

Keys

Function

Description

Note

39

1.
Beep Beep Beep___
Beep Beep Beep___

2. Single flash

1.
Beep___Beep___
Beep___Beep .....

Zone 1 Sensor 1

2. Double flash

Zone 3 Sensor 2 window
open

Advertising
This manual is related to the following products: