Setting Switches and Jumpers

Hardware Preparation and Installation

CPCI-6115 CompactPCI Single Board Computer Installation and Use (6806800A68D)

37

2.5.2

Setting Switches and Jumpers

Figure 2-2 on page 35

illustrates the placement of the switches, jumper headers, connectors

and LED indicators on the CPCI-6115. Use this figure to help identify the approximate location
of the jumpers on the CPCI-6115. There are seven manually configured headers on the
baseboard. They are described in the following table:

Table 2-5 CPCI-6115 Jumper Map

Reference

Function

Comment

J6

Bus Mode Select
Header

Jumper pins 1-2 for 60x mode
Jumper pins 2-3 for MPX mode

J9

Stand-Alone Operation
Header

Jumper pins 1-2 for Stand-Alone operation (no CPCI bus)

J10

Flash Boot Bank Select
Header

No jumper or jumper pins 1-2 for Bank A (32 MB)

Jumper pins 2-3 for Bank B (8 MB)

J15

+/-12 V Present Header

Jumper pins 1-2 allows board operation without +/- 12 V
power

J20

Safe Start ENV Header

No jumper or jumper pins 1-2 for normal ENV settings

Jumper pins 2-3 for safe ENV settings

J25

SROM Initialization
Enable Header

Jumper pins 1-2 to enable SROM init

No jumper or jumper pins 2-3 to disable SROM init

J99

Flash Bank A Write
Protect Header

Jumper pins 1-2 to enable Bank A Flash Write

No jumper to disable Flash Writes

SW2

Manual Geographic
Address -

OFF (default) - GA from CompactPCI backplane

ON - generate address locally

Damage of the Product
Setting/resetting the switches during operation can cause damage of the product.
Check and change switch settings before you install the product.