Mercedes-Benz CS1000 User Manual

Page 110

Advertising
background image

)  2   

)  2   

)  2   

)  2   

110

46: +! /# 7)79

46: +! /# 7)79

46: +! /# 7)79

46: +! /# 7)79

READING ACTUAL VALUES
1. IGNITION : Position 1
2. Press the AUTO button
3. Set both temperature selectors to 72 degrees F.
4. Press the REST button for more than 5 seconds.
5. The left display will alternately show the number "1" and the in-car temperature.
6. Press the AUTO button and the next component number and its value will be displayed.
7. Press the REST button to end the test program.

COMPONENT UNDER TEST

Number

Component

01

In-Car Temperature Sensor with Aspirator Blower (B10/4)

02

Outside Temperature Sensor (B14)

03

Left Heater Core Temperature Sensor (B10/1)

04

Right Heater Core Temperature Sensor (B10/1)

05

Evaporator Temperature Sensor (B10/6)

06

Engine Coolant Temperature (ECT) Sensor (A/C) (B1/4)

07

Refrigerant Pressure in Bar

08

Refrigerant Temperature Sensor (B12/1)

10

Blower Control Voltage

11

Emissions (Refrigerant Leak) Sensor (B31)

12

Sun (Excessive Heat) Sensor (B32)

20

Control Current for Auxiliary Fan exp. : 7 = 7 mA

21

Engine RPM. example 00..99 (x100) = 9900

22

Vehicle Speed

23

PIN 58D exp. 99.0 = 99% of Battery Voltage

24

Battery Voltage : 12.8 = 12,8 Volt

40

Software Version Encoded

41

Hardware Version

Advertising