MOTOR DATA

Power Code Description — PSH Models ➀ ➂ ➃

Model

PSH130

PSH150

PSH170

PSH225

PSH280

PSH340

Power

Electric

Code

Power

Horsepower

01

115/60/1

1/6

1/6

1/6

1/3

1/2

1/2

02

230/60/1

1/6

1/6

1/6

1/3

1/2

1/2

04

200/60/3

1/3

1/3

1/3

1/3

1/2

1/2

05

200/460/60/3

1/3

1/3

1/3

1/3

1/2

1/2

Power Code Description — BSH Models ➁ ➂ ➃ ➄

Power

Model

BSH130

BSH150

BSH170

BSH225

BSH280

BSH340

Code

Electric Power

HP

Drive

HP

Drive

HP

Drive

HP

Drive

HP

Drive

HP

Drive

01

115/60/1

1/3

-13

3/4

-18

3/4

-18

3/4

-18

1

-16

1-1/2

-16

02

230/60/1

1/3

-13

3/4

-18

3/4

-18

3/4

-18

1

-16

1-1/2

-16

03

200-208/60/3

1/3

-13

3/4

-18

3/4

-18

3/4

-18

1

-16

1-1/2

-16

04

230/460/60/3

1/3

-13

3/4

-18

3/4

-18

3/4

-18

1

-16

1-1/2

-16

81

575/60/3

1/3

-14

3/4

-18

3/4

-18

3/4

-18

1

-16

1-1/2

-178

05

115/60/1

1/4

-21

1/2

-25

1/2

-25

3/4

-22

1

-18

1

-29

06

230/60/1

1/4

-21

1/2

-25

1/2

-25

3/4

-22

1

-18

1

-29

07

200-208/60/3

1/4

-21

1/2

-25

1/2

-25

3/4

-22

1

-18

1

-29

08

230/460/60/3

1/4

-21

1/2

-25

1/2

-25

3/4

-22

1

-18

1

-29

82

575/60/3

1/4

-165

1/2

-25

1/2

-25

3/4

-22

1

-18

1

-29

09

115/60/1

1/3

-15

1/2

-22

1/2

-22

1

-16

1-1/2

-23

10

230/60/1

1/3

-15

1/2

-22

1/2

-22

1

-16

1-1/2

-23

11

200-208/60/3

1/3

-15

1/2

-22

1/2

-22

1

-16

1-1/2

-23

2

-32

12

230/460/60/3

1/3

-15

1/2

-22

1/2

-22

1

-16

1-1/2

-23

2

-32

83

575/60/3

1/3

-166

1/2

-22

1/2

-22

1

-16

1-1/2

-177

2

-32

13

115/60/1

1/3

-57

3/4

-25

14

230/60/1

1/3

-57

3/4

-25

15

200-208/60/3

1/3

-57

3/4

-25

16

200/460/60/3

1/3

-57

3/4

-25

84

575/60/3

1/3

-167

3/4

-25

Motor Data and Total Unit Power Requirements — PSH Models

Voltage

115/60/1

230/60/1

200-208/60/3

230/460/3

Motor

Motor

Total

Total

Motor

Motor

Total

Total

Motor

Motor

Total

Total

Motor

Motor

Total

Total

HP

Amps

Rpm

Amps

Watts

Amps

Rpm

Amps

Watts

Amps

Rpm

Amps

Watts

Amps

Rpm

Amps

Watts

1/6

2.8

1075

4.6

400

1.5

1075

2.5

400

1/3

5.4

1075

7.2

610

2.5

1075

3.5

610

1.9

1140

2.8

560

2.2/1.1

1140

3.2/1.6

560

1/2

7.5

1075

9.3

800

3.5

1075

4.5

800

2.6

1140

3.5

850

3.0/1.5

1140

4.0/2.0

850

Unit Power Requirements - Blower BSH Models

115/60/1

230/60/1

200-208/60/3

230/460/60/3

575/60/3

Total

Total

Total

Total

Total

Total

Total

Total

Total

Total

HP

Amps

Watts

Amps

Watts

Amps

Watts

Amps

Watts

Amps

Watts

1/4

7.2

520

3.7

520

2.5

500

2.4/1.2

500

0.9

500

1/3

6.4

515

3.3

515

2.7

530

2.6/1.3

530

1.1

530

1/2

10.3

730

4.8

730

3.4

730

3.6/1.8

730

1.3

730

3/4

12.8

1000

6.5

1000

4.1

970

3.8/1.9

970

1.5

970

1

15.2

1210

7.7

1210

4.9

1230

4.8/2.4

1230

1.9

1230

1-1/2

16.8

1690

8.5

1690

6.5

1630

6.2/3.1

1630

2.3

1630

2

-

-

-

-

8.6

2080

7.6/3.8

2080

2.7

2080

Permanent split capacitor motors on models PSH130 through PSH340.

Split phase motors for 1/4 through 3/4 hp motors. Capacitor start motors are 1 through 2 hp.

Whenever 230V/1

φ

or 230V/3

φ

power is used, it is necessary to specify 230V/25V controls. Whenever 460V/3

φ

power is used, it is necessary to specify 230V/25V

controls and in addition, a 460V/230V 75VA step-down transformer (by others) is required. On 230V/3

φ

or 460V/3

φ

systems, the motor starter coil voltage (motor

starter by others) must be 230V. For 200V/3

φ

systems, the motor starter coil voltage (motor starter by others) must be 200V.

All motors used are produced, rated and tested by reputable manufacturers in accordance with NEMA standards and carry the standard warranty of both the motor
manufacturer and Modine. All motors are totally enclosed. Single phase motors have built-in thermal overload protection.

575V motor available on blower units only.

Voltage

Heater Parts from ACF Greenhouses

Advertising