Melsec-q, 10 troubleshooting – MITSUBISHI ELECTRIC QJ71C24N User Manual

Page 269

Advertising
background image

10 - 18 10 - 18

MELSEC-Q

10 TROUBLESHOOTING

Protocol

Error code

(Hexa-

decimal)

Error

Error Contents

Signal

name

Corrective action

MC

Non

Proce-

dure

Bidire-

ctional

7E52

H

User frame

overwrite error

A written frame No. overwrite request was issued.

PRO

Change the write destination to

an unwritten frame No.

When overwriting, delete the

given No. beforehand.

7E53

H

User frame access

data error

A nonexistent command was designated in a

subcommand.

Byte count exceeding the number of bytes that can

be requested was designated.

PRO

Check and correct the external

device transmit message and

restart data communications.

7E54

H

Modification

allowed error

Flash ROM write allow/prohibit designation from GX

Configurator-SC is set to OFF.

At the switch setting on GX Developer, modification

allowed switch was set to OFF.

PRO

Set to ON at GX Configurator-

SC.

Set to ON at GX Developer.

7E55

H

User frame data

error

There is an error in the user frame variable data.

PRO

Check and correct the external

device transmit message and

restart data communications.

7E56

H

System error

The OS of the Q series C24 detected some error.

(

1)

7E57

H

Flash ROM write

error

Cannot write to Flash ROM normally.

PRO

Re-execute the write operation.

If the error is generated again,

replace the module.

7E58

H

Mode modification

error

There was an error in the mode No. or transmission

specification designated contents when changing

the mode.

PRO

Check and correct the contents

of the external device transmit

message and restart data

communications.

Recheck the switch setting on

the Q series C24.

7E59

H

Flash ROM write

count over limit

error

Flash ROM written 1,000 times

Review the program.

Rewrite the flash ROM area

(address: 2401

H

) of the buffer

memory to 0 and restart data

communications.

7E5F

H

I/O number error

on requested

module

I/O number of requested module is incorrect.

Correct the I/O number of the

module to which data is sent.

7E60

H

Device monitoring

duplicate

registration error

PLC CPU monitoring registration was performed

twice.

Cancel the PLC CPU monitoring

and perform the PLC CPU

monitoring registration again.

7E61

H

Cycle time units

range error

Setting value of cycle time units is out of range.

Correct the setting value of the

cycle time units.

7E62

H

PLC CPU

monitoring function

error

Setting value of PLC CPU monitoring function is out

of range.

Correct the setting value of the

PLC CPU monitoring function.

7E63

H

Transmission

measure setting

error

Setting of transmission measure of the PLC CPU

monitoring is incorrect.

Correct the setting value of the

transmission measure.

7E64

H

Registration point

range error

Registration point (word/bit) is out of range.

Correct the setting value of the

registration point (word/byte)

7E65

H

PLC CPU abnormal

monitoring number

error

Setting value of the PLC CPU abnormal monitoring

is out of range.

Correct the setting value of the

PLC CPU abnormal monitoring.

7E66

H

Monitoring

condition error of

monitoring device

Setting value of transmission condition is out of

range.

Correct the setting value of the

transmission condition.

7E67

H

CPU abnormal

monitoring setting

value error

Setting value (fixed value) of CPU abnormal

monitoring is out of range.

Correct the setting value (fixed

value) of the CPU abnormal

monitoring.

7E68

H

Transmission

condition range

error of monitoring

device

Setting value of transmission condition (condition

agreement transmission) is out of range.

Correct the setting value of the

transmission condition

(condition agreement

transmission).

7E69

H

CPU abnormal

monitoring setting

value error

Setting value (fixed value) of CPU abnormal

monitoring is out of range.

Correct the setting value (fixed

value) of the CPU abnormal

monitoring.

Advertising