TEST SETUP & TESTING

How to Configure the IFR 3902 / IFR 2968 Manual Test Screen

For IFR 3902, perform the following steps to configure the manual test screen:

1. Press “TEST” soft key.

2. Press “TAB” soft key to select RF Settings.

3. Enter “3605” for Control Channel.

4. Enter “3605” for Traffic Channel.

5. Enter “3” for Slot.

6. Enter “-75” for RF Gen Level.

7. Select “Expected” and “30.0dBm/1W” for Mobile Power.

8. Press “TAB” to select Tx Measurements.

9. Select “Normal” for Burst.

This completes the test equipment configuration setup.

Note: The System Setup Configuration Data is saved even after the power

is turned off. However, the Manual Test Setup is not saved.

For IFR 2968, perform the following steps to configure the manual test screen:

1. To enter “Manual test” screen, press “Manual” soft key.

2. For MTP810 Ex, press “Control Channel” soft key. Thereafter, “3605” and

press “Control Channel” soft key (IFR 3605 = Rx 390.125000MHz).

3. Press “Traffic Channel” soft key. Enter “3605” or “2400” and press “Traffic

Channel” soft key. The marker goes to Timeslot. Enter “3” and press “Traffic

Channel” soft key. (Note that the Traffic Channel number changes

automatically after entering the Control Channel number).

4. Press “RF Gen Level” soft key. Thereafter, enter “-75” and press “dBm” data

keys followed by “RF Gen Level” soft key.

5. Press “Mobile Power” soft key, enter 30 dBm/1W, using soft key.

6. Press “Burst Type” soft key and “Normal” soft key.

This completes the test equipment configuration setup.

Note: The System Setup Configuration Data is saved even after the power
is turned off. However, the Manual Test Setup is not saved.