Maintenance, Routine maintenance schedule, Cold weather conditions – Makita MAC5200 User Manual

Page 12

Advertising
background image

Page

12

MAINTENANCE

WARNING: UNIT CYCLES
AUTOMATICALLY WHEN
POWER IS ON. WHEN
DOING MAINTENANCE,
YOU MAY BE EXPOSED
TO VOLTAGE SOURCES,
COMPRESSED AIR OR
MOVING PARTS. PERSONAL
INJURIES CAN OCCUR.
BEFORE PERFORMING
ANY MAINTENANCE OR
REPAIR, UNPLUG THE
COMPRESSOR AND BLEED
OFF ALL AIR PRESSURE.

To ensure efficient operation and
longer life of the air compressor
unit, a routine maintenance
schedule should be prepared
and followed. The following
routine maintenance schedule is
geared to a unit in a normal
working environment operating
on a daily basis. If necessary, the
schedule should be modified to
suit the conditions under which
your compressor is used. The
modifications will depend upon
the hours of operation and the
working environment.
Compressor units in an
extremely dirty and/or hostile
environment will require a
greater frequency of all
maintenance checks.

ROUTINE

MAINTENANCE

SCHEDULE

1. Drain water from the air tank,

any moisture separators or
transformers.

2. Check for any unusual noise

and/or vibration.

3. Manually check all safety

valves to make sure they are
operating properly.

4. Inspect air filter, replace if

necessary.

5. Inspect air lines and fittings for

leaks; correct as necessary.

Each year of operation or if a
problem is suspected:
• Check condition of air

compressor pump intake and
exhaust valves.

• Check condition of check

valve. Replace if damaged or
worn out.

Filling with Oil:
1.Remove the oil filler plug.
2.Slowly pour the proper oil into

the pump crankcase.

3.Always keep oil level in the

middle of the sight glass.

Changing the Oil:
Note: Every 300 hours or 3
months, whichever comes first.
1.Remove the oil drain plug.

COLD WEATHER CONDITIONS:

AMBIENT

SAE ISO

TEMPERATURES AT

VISCOSITY

VISCOSITY

POINT OF OPERATION

-16°C TO 0°C (3.2°F - 32°F)

SAE 10W

ISO 32

1°C TO 26°C (33.8°F - 78.8°F)

SAE 20W

ISO 68

ABOVE 27°C (80.6°F)

SAE 30W

ISO 100

Advertising