PROBLEM

Motor will
not run.
(con’t)

Regulator
knob has
continuous
air leak.
Regulator
will not
shut off at
air outlet.

CAUSE

• Check valve is

stuck open.

• Loose electrical

connections.

• Possible

defective
capacitor.

• Paint spray on

internal motor
parts.

• Possible

defective
motor.

• Fuse Blown,

circuit breaker
tripped.

• Pressure

unloader valve
on pressure
switch has not
unloaded head
pressure.

Dirty or damaged
regulator internal
parts.

CORRECTION

• Remove and clean, or replace.

• Check wiring connection inside

pressure switch and terminal box
area.

• Return to an Authorized Warranty

Service Center for inspection or
replacement if necessary.

• Have checked at an Authorized

Warranty Service Center. Do not
operate the compressor in the paint
spray area. See flammable vapor
warning.

• Have checked at an Authorized

Warranty Service Center.

1.Check fuse box for blown fuse and

replace. If necessary, reset circuit
breaker. Do not use a fuse or circuit
breaker with higher rating than
specified for your particular branch
circuit.

2.Check for low voltage conditions

and/or proper extension cord.

3.Disconnect the other electrical

appliances from circuit or operate
the compressor on its own branch
circuit.

• Bleed the line by pushing the lever

on the pressure switch to the "off"
position; if the valve does not open,
replace it.

Replace regulator.