Digital Hookup

This example describes the hookup for the D8B console equipped for digital I/O
(DIO•8 or OPT•8).

Cables & Hardware

(3) DIO

8 or OPT

8 cards for D8B

(1) Apogee Clock I/O card for D8B (if D8B is the slave)
(6) ADAT optical cables
(1) 75

Ω BNC word clock cable

Hookup

1. Connect three ADAT optical cables from the SDR24/96 DIGITAL optical

outputs to the optical inputs on the corresponding D8B I/O cards.

2. Connect three ADAT optical cables from the SDR24/96 DIGITAL optical

inputs to the optical outputs on the corresponding D8B I/O cards.

3. When the D8B is the clock master, the SDR24/96 can derive its clock from

the Digital Optical input. When the SDR24/96 is the clock master, connect
the WORD CLOCK OUT on the SDR24/96 to the WORD CLOCK IN on
the D8B (the D8B must have an Apogee Clock I/O card installed).

SDR24/96 Settings

1. Set the Input Type (SETUP:I/O:INPUT TYPE SELECT) to ADAT for

Inputs 1-8, 9-16, and 17-24.

2. If the SDR24/96 is the clock master, set the Sample Clock to Internal. If

the SDR24/96 is a clock slave, set the Sample Clock to ADAT A (or B or C).
(SETUP:Sync:SClk:ADAT A).

3. Set the Sample Rate to 44.1 kHz or 48 kHz according to your preference.

Console Settings

1. If you have DIO

8 cards installed, set the Tape Input and Tape Output

format for each card to ADAT. OPT

8 cards need no configuration.

2. If the D8B is the clock master, set the Sample Clock to either 44.1 k

Internal

or 48 k Internal. If it is a clock slave, then set the Sample Clock

to either 44.1 kHz or 48 kHz to match the Sample Rate selected on the
SDR24/96. Set the Apogee Clock to Word Clock.