Sdr 24/ 96 – MACKIE SDR96 User Manual

Page 18

Advertising
background image

18

SDR24/96

SDR

24/

96

3. Select 1-8. The LCD display

shows you the current setting for
outputs 1-8, either Direct or
Custom

.

4. Select Direct for direct track-to-output playback (i.e., Track 1 to Output 1,

Track 2 to Output 2, etc.).

5. Select Custom to route tracks to different output numbers.

6. Press the Inc (increment) and

Dec

(decrement) buttons to

change the output number that is
assigned to Track 1. Select Apply
to save the change.

7. Press the Page Right button to scroll to the next track. Repeat step 6

for Track 2, and so on.

8. Select Exit when finished with Tracks 1-8 to return to the previous menu.

Press the Page Left button to return to the TRACK OUTPUT SELECT
menu to edit tracks 9-16 and 17-24.

9. Press the SETUP button when done.

Notes:

You cannot route a track to more than one output.

You cannot assign more than one track to a single output. Attempting to do

so will cause the output assignments to switch places for the two tracks.

Input Type Setup

The SDR24/96 can read only one input for each track, either analog or digital. This
must be configured in the Setup menu. Since these settings depend on how the SDR
is connected to the console, these are global settings, and are project independent.

To configure the input type format:

1. Press SETUP to enter the

SETUP MENU

.

2. Select I/O.

3. Press the Page Right button

two times to enter the INPUT
TYPE SELECT

menu.

4. Select 1-8. The LCD display

shows you the current input
settings for the 8 inputs selected.
Select Analog when using the
DB25 Analog inputs, and ADAT when using the Digital optical inputs.

5. The SDR24/96 also provides the

option of customizing each input
individually for either analog or
digital formats. Select the Custom
button and use the Page Left and Page Right buttons to scroll
through the 8 inputs. Choose either analog or digital for each input.

6. Repeat steps 4 and 5 for inputs 9-16 and 17-24.

TRK 1- 8 OUT: Direct

Direct Custom Exit

TRK 1 OUT: 1 ( 1) >

Inc Dec Apply Exit

Track

New

Setting

Current

Setting

SETUP MENU >

Record I/O Sync Transp

< INPUT TYPE SELECT

INP: 1-8 9-16 17-24

INP 1- 8 TYPE: ADAT

Analog ADAT Custom Exit

INP 1 TYPE: ADAT >

Analog ADAT Exit

Note: The front

panel display’s back-

light switches off

after ten minutes of

inactivity. You can

revive it at any time

by pressing either

the Page Left [<] or

Page Right [>] but-

ton, or any Select

button below the

display.