7. symbols and definitions, Section 4 − installation, 1. specifications – Miller Electric 812 User Manual

Page 18

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-278 Page 10

3-7. Symbols And Definitions

Some symbols are found only on CE products.

NOTE

A

Amperes

Amperage/Voltage

Control−Panel

Gas Tungsten Arc

Welding (GTAW)

Shielded Metal Arc

Welding (SMAW)

Temperature

Wire Feeder

Arc Force (DIG)

Gas Metal Arc

Welding (GMAW)

Output

Circuit Breaker

Remote

V

Volts

Positive High In-

ductance Weld

Output Terminal

Positive Low In-

ductance Weld

Output Terminal

Negative Weld

Output Terminal

Input

On

Off

Percent

Direct Current

U

0

Rated No Load

Voltage (Average)

U

1

Primary Voltage

U

2

Conventional Load

Voltage

Line Connection

I

1

Primary Current

I

2

Rated Welding

Current

X

Duty Cycle

Three-Phase

Transformer

Rectifier

IP

Degree Of

Protection

Three-Phase

S

1

KVA

Hz

Hertz

S

Suitable For Areas

Of Increased

Shock Hazard

Protective Earth

(Ground)

SECTION 4 − INSTALLATION

4-1. Specifications

Model

IP

Rated

Welding

Amperage/

Voltage

Max

Amperes Input at Rated Load Output,

50 or 60 Hz, Three-Phase

Model

IP

Rating

Welding

Output

Voltage

Range DC

Max

OCV−DC

230

V

380

V

400

V

440

V

460

V

520

V

575

V

KVA

KW

650

21M

650 A @ 44

Volts DC,

50 − 815 A

In CC Mode

71 (70) VDC

In

CC Mode**

126

3.8*

77

1.9*

73

1.8*

66

1.6*

63

1.9*

54

1.1*

50.4

1.4*

50

1.52*

34.8

0.76*

650

Amp

21M

Volts DC,

100% Duty

Cycle

10 − 65 V In

CV Mode

40 (66) VDC

In

CV Mode**

3.8*

1.9*

1.8*

1.6*

1.9*

1.1*

1.4*

1.52*

0.76*

*While idling

( ) Indicates specification differences for CE models
**Open-circuit voltage is 26 volts dc if unit is equipped with optional low open-circuit voltage.