13. tig (gtaw) cable connections, 14. remote 14 receptacle rc8 information – Miller Electric 812 User Manual

Page 26

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-278 Page 18

4-13. TIG (GTAW) Cable Connections

+

+

Gas Flowmeter/

Regulator

HIGH

INDUCTANCE

Optional HF Unit

!

Turn Off power before making connections.

.

For better performance for most GTAW applications, it is
recommended that electrode negative (DCEN) weld output

connections be made to the high Inductance weld output ter-

minal. Make connections as shown.

4-14. Remote 14 Receptacle RC8 Information

Socket

Information

24 VOLTS AC

A

24 volts ac. Protected by supplementary protector CB2.

24 VOLTS AC

B

Contact closure to A completes 24 volts ac contactor control circuit.

C

Command reference; 0 to +10 volts dc (CC), +10 volts dc (CV).

REMOTE OUTPUT CONTROL

D

Remote control circuit common.

E

0 to +10 volts dc input command signal from remote control.

F

Current feedback; 1 volt per 100 amperes.

H

Voltage feedback; 1 volt per 10 arc volts.

115 VOLTS AC

I

115 volts, 15 amperes, 60 Hz ac. Protected by supplementary protector CB1.

115 VOLTS AC

J

Contact closure to I completes 115 volts ac contactor control circuit.

GND

K

G

Chassis common.
Circuit common for 24 and 115 volts ac circuits.

REMOTE POWER ON/OFF

*

To remote On/Off switch

REMOTE POWER ON/OFF

*

To remote On/Off switch.

REMOTE VOLTAGE SENSING

*

Voltage sensing signal from Negative (−) weld output terminal.

REMOTE VOLTAGE SENSING

*

Voltage sensing signal from Positive (+) weld output terminal.

* Not Used

Advertising