5-7. Weld Process/Polarity Table

Weld Process

Weld Polarity

Cable Connections

Weld Process

Weld Polarity

Wire Drive Lead

Work Clamp Lead

GMAW − Solid wire with shield-

ing gas

DCEP − Reverse polarity

Connect to positive (+) out-

put terminal

Connect to negative (−) output

terminal

FCAW − Self-shielding wire −

no shielding gas

DCEN − Straight Polarity

Connect to negative (−)

output terminal

Connect to positive (+) output

terminal

5-8. Changing Weld Polarity

.

Connection hardware must be
tightened with proper tools. Do

not just hand tighten hardware.

A loose electrical connection

will cause poor weld perfor-

mance and excessive heating

at the terminal block.

1

Lead Connections For Direct

Current Electrode Negative

(DCEN)

2

Lead Connections For Direct

Current Electrode Positive

(DCEP)

Always read and follow wire

manufacturer’s recommended po-

larity, and see Section 5-7.
Close door.