OM-228 042 Page 34

8-7. Maintaining Gun

Ref. 800 797-D

Turn off welding power

source/wire feeder.

1

Nozzle

2

Contact Tip

3

Adapter

4

Head Tube

Cut off wire and disconnect gun

from feeder
Remove nozzle contact tip and

adapter from head tube.
5

Liner

Unscrew and remove liner.
Lay gun cable out straight before

installing new liner.
Blow out gun casing.
Reassemble gun in reverse order

from taking it apart. Be sure liner

stickout is approximately 3/4 in. (20

mm).

.

Wire size stamped on tip −
check and match wire size.

.

Thread wire according to Sec-
tion 5-12
.