needed), insulation shield, roof flashing, chimney cap,
and any other needed accessories. Follow the
manufacturer’s instructions when installing the chimney
and accessories. In addition, be sure to maintain all
manufacturers’ recommendations for the proper
clearances to the chimney.


Whenever possible, choose an interior chimney. An
interior chimney heats up more quickly and retains its
heat; thus promotes a better draft and discourages the
formation of creosote. An exterior chimney does not
benefit from the warmth of being surrounded by the

building, so it typically operates at lower flue
temperatures than an interior chimney. An exterior
chimney’s draft is not as strong and may experience
increased creosote accumulation.

There are two ways to install a prefabricated metal
chimney:
 An interior installation where the chimney passes

inside the residence through the ceiling and roof.


REMOVE DAMPER OR WIRE IT OPEN

 An exterior installation where the chimney passes

through the wall behind the Fireplace Insert then up
the outside of the residence.

Hearthstone Quality Home Heating Products, Inc. ® Morgan Model 8470

10

Typical Installation

Chimney Cap

Storm Collar

Flashing

Masonry Chimney

Adjustable Roof

Clay tile or

other Liner

Flue liner with

required air space

Stainless steel

chimney connector

must extend to

flue liner

Min. 8" masonry

thickness in front

of smoke chamber

Damper plateremoved or fastened inopen position. Seal with non-combustible material.

or other

Min. clearance allowed

with insert listing

Floor protection in accordance

with insert listing

Figure 7 Connecting to a chimney