Hearthstone Quality Home Heating Products, Inc. ® Morgan Model 8470

18

T

ROUBLESHOOTING

G

UIDE

PROBLEM

POSSIBLE CAUSE

SOLUTIONS

STOVE SMOKES

Operating Technique

Fully open the primary air control one minute before opening doors.

Cold Chimney

Preheat the chimney when first starting a fire.

Blocked Chimney

Examine the chimney and stovepipe for blockage or creosote
accumulations.

Oversized Chimney

Reline the chimney to the appropriate diameter

Undersized Chimney

Install a draft inducer or replace the chimney.

Chimney Too Short

Lengthen the chimney.

Air Infiltration Into The
Chimney

Seal chimney connections and openings in clean-out doors.

More Than One Appliance
Connected to the Flue

Disconnect all other appliances and seal openings.

BACK-PUFFING OR
GAS EXPLOSIONS

Operating Technique

Fully open the primary air control one minute before opening the
door and keep it fully open for a few minutes after reloading.

Extra Low Burn Rate

Burn the Fireplace Insert at a higher burn rate.

Chimney Down-draft

Install a chimney cap.

Excessive Ash Build-up

Empty ashes more frequently.

UNCONTROLLED
OR SHORT BURN

Unsealed or Open Door

Close the door tightly or replace the gaskets.

Excessive Draft

Check the installation. Operate at LOW BURN. Install stovepipe
damper.

Deteriorated Cement Seals

Reseal the Fireplace Insert with furnace cement.

Extra Long Chimney

Shorten the chimney. Install stovepipe damper.

Oversized Chimney

Reline the chimney to the proper diameter.

High Winds or Hilltop
Location:

Install a chimney cap.

Excessive Draft

Draft in excess of 0.1 wc should be corrected with a stovepipe
damper

INSUFFICIENT HEAT Poor Quality or Green

Wood

Use only air-dried wood, preferably dried at least one year.

Low Burn Rate

Operate the Fireplace Insert at a higher burn rate.

Air Insulated Chimney

Replace with a pre-fabricated insulated chimney system or a
properly sized masonry chimney.

Cold Exterior Chimney

Reline or insulate the chimney.

Leaky

Stovepipe

or

Chimney

Check the installation.

Too Much Heat Loss From
House

Caulk windows, seal openings in home.

BLISTERING OF
ENAMEL CASTING

Operating Technique

Do not over-fire the Fireplace Insert. Monitor Fireplace Insert
temperatures. Use seasoned wood only.

Excessive Draft

Check the DRAFT. A damper may be required. Operate the
Fireplace Insert at a LOW BURN range.