Safety label, Afety, Abel – Morgan & Company HEARTHSTONE 8470 User Manual

Page 22

Advertising
background image


S

AFETY

L

ABEL

CONTACT YOUR LOCAL BUILDING

OFFICIALS ABOUT RESTRICTIONS

Listed Room Heater, Solid Fuel Type

Intertek Testing

Services NA, inc.

Manufactured by:

317 Stafford Ave.

Morrisville VT 05661

SERIAL #
MODEL NAME: MORGAN 8470
TESTED TO: UL 1482, ULC S628, UL 737

Do not use grate or elevate fire. Build
wood fire directly on stone.

Risk of smoke and flame spillage,
operate only with doors fully open
or fully closed.

:

WARNINGS

“PREVENT HOUSE FIRES”

Clearance to Combustible Materials*

Date of Manufacture

2003 2004 2005 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

DO NOT REMOVE OR COVER THIS LABEL

MADE IN USA

3300-615

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with July 1, 1990 particulate emissions standards

* Refer to the Installation Manual for
additional clearance information.

Kit # 94-79700

Screen Kit # 94-69700
Blower Kit # 94-57700
Surround Caps Kit # 94-597051
Surround Extension Kit # 94-5970010

Mantle Shield Kit

OPTIONAL KITS:

WN 04380

INSPECTION IN YOUR AREA

AND INSTALLATION

TYPE OF FUEL: Solid Wood Only

CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP
CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
INSPECT AND CLEAN CHIMNEY AND CONNECTOR
FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE,
CREOSOTE BUILDUP MAY OCCUR RAPIDLY.

When installed on a combustible floor,
non-combustible floor protection, with a
R value of 1.0 or greater, is required to
cover the area beneath the heater, 16” in
front of, and 8” beyond both sides of the
glass opening. (See “Top View” diagram

Do not obstruct space under heater.

Do not overfire. If the heater or
chimney connector glows, you are
overfiring.

STOVE

D

Install and use only in accordance with
manufacture’s installation instructions and
your local building codes.

Connect to a code-approved masonry chimney
or listed factory-built fireplace chimney with a
direct flue connector into the first chimney liner
section.

CAUTION: Special methods are required when
passing chimney through a wall or ceiling, refer
to local building codes. Do not connect this unit
to a chimney flue serving another appliance.

NOTE: Replace glass only with 5mm CERAMIC
or NEOCERAM glass.

STOVE

SI

D

E

W

A

LL

A

C

B

TR
IM

Front View

Top View

E

HEARTH

“TRIM” is defined as any combustible
protruding 1/2” or less from the wall.

A - 34” (87cm)
A - 22” (56cm) with Mantle Shield
B - 13” (33cm)
C - 3” (8cm)
D - 34” (87cm)
E - 16” (41cm)

Hearthstone Quality Home Heating Products, Inc. ® Morgan Model 8470