Figure 5: Combustible Clearances for Vent Pipe

Framing Dimensions:

Figure 6: Minimum Framing Dimensions

Firebox framing can be built before or after the appliance is set in place. Framing should be positioned to
accommodate wall covering and fireplace facing mantel. Figure 6 shows a typical framing of this appliance. Refer to
Figure 1 for firebox dimensions. All minimum clearances must be maintained in framing the appliance. The framing
headers may rest on the top of the framing spacers.

CAUTION

Measure fireplace dimensions and verify framing methods & wall covering details before framing

construction begins.