PRODUCT SPECIFICATIONS:

Gas Pressure (Inches W.C.)

Models Number

Gas Type

Control Type Max Btu

Max

Min

Manifold

320DV4136NV

Natural Gas

Milli-volt

26000

10.5

4.0

3.5

320DV4136PV

Propane/LPG

Milli-volt

26000

13.0

11.0

10.0

320DV4742NV

Natural Gas

Milli-volt

28000

10.5

4.0

3.5

320DV4742PV

Propane/LPG

Milli-volt

28000

13.0

11.0

10.0

320DV4136NE

Natural Gas

Electronic Ign

26000

10.5

4.0

3.5

320DV4136PE

Propane/LPG Electronic Ign

26000

13.0

11.0

10.0

320DV4742NE

Natural Gas

Electronic Ign

28000

10.5

4.0

3.5

320DV4742PE

Propane/LPG Electronic Ign

28000

13.0

11.0

10.0

High Altitude Installations
Gas rate shown above is for altitudes up to 2000 ft. When installing this fireplace at an elevation above 2000 ft, it
may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input should
be reduced four percent (4%) for each 1000 ft above sea level, unless the heating value of the gas has been reduced.
Consult your local dealer or gas authority for assistance in determining the proper orifice at your location.

LISTING & CODE APPROVAL:
The above models have been tested and certified by the applicable laboratories to the standards listed below.

MODEL

LAB.

TYPE

CERTIFICATION STANDARD

320DV4136 Series

CSA Vented Gas Fireplace Heaters ANSI Z21.88-1998

CSA 2.33-M98

320DV4742 Series

CSA Vented Gas Fireplace Heaters ANSI Z21.88-1998

CSA 2.33-M98


In addition, this appliance may be installed in an aftermarket, permanently located, manufactured (mobile home,
where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
This appliance is not convertible for use with other gases, unless a certified kit is used.