Monessen Hearth 3000 SERIES User Manual

Page 22

Advertising
background image

G

G

A

A

S

S

L

L

I

I

N

N

E

E

A

A

N

N

D

D

E

E

L

L

E

E

C

C

T

T

R

R

I

I

C

C

A

A

L

L

I

I

N

N

S

S

T

T

A

A

L

L

L

L

A

A

T

T

I

I

O

O

N

N

20

Figure 19: Gas Pressure Check at Gas Valve

Electrical Wiring:

CAUTION

Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off

when connecting to main electrical power supply or performing service. All wiring shall be in compliance

with all local, city, and state codes. The appliance, when installed, must be electrically grounded in

accordance with local codes, or in the absence of local codes, with the

National Electrical Code ANSI / NFPA 70 (latest edition)

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and

dangerous operations. Verify proper operation after servicing.

Standing Pilot Ignition Wiring-Millivolt Control:

WARNING

Do not connect 110-120 VAC to the Remote Wall Switch, DC Remote Control or the Millivolt Control Valve.

The appliance will malfunction or the valve will be destroyed.

Remote Wall Switch
A remote wall switch and fifteen (15) feet of 18 Ga. wire are provided as standard with this fireplace. The
wire has been pre-wired at the valve and routed through the right side, outer shell. (Access is also available
on the left side through the square hole on that side). Position the wall switch inside of a junction box (not
provided) at the desired location on the wall. Refer to Figure 20: Wiring Diagram for Standing Pilot -
Millivolt System. Do not extend beyond the wall switch wire length provided.

NOTE

Extended lengths of wire may cause the fireplace not to function properly. Longer length of wire is permitted

if the wire is made out of larger gauge (diameter) wire. Always check with local code

Advertising