For Horizontal Termination

Figure 16: Horizontal Vent Termination Location

#

A=12 inches

Clearance above the grade, a veranda, porch, deck, or balcony

#

B=12 inches

Clearance to window or door that may be opened.

C=12 inches

Clearance to permanently closed window.

D*=18 inches

Vertical clearance to ventilated soffit located above the terminal within a horizontal
distance of 2 feet from the centerline of the terminal.

E*=18 inches

Clearance to unventilated soffits.

F=9 inches

Clearance to an outside corner.

G=6 inches

Clearance to an inside corner.

#

H=3 feet

Not to be installed above a gas meter/regulator assembly within 3 feet horizontally from
the centerline of the regulator.

#

I=6 feet

Clearance to service regulator vent outlet.

#

J=12 inches

Clearance to non-mechanical air supply inlet to building or the combustion air inlet to
any other appliance.

#

K=6 feet

Clearance to a mechanical air supply inlet

#

L**=7 feet

Clearance above a paved sidewalk paved driveway located on public property.

#

M***=12 inches Clearance under veranda, porch, deck, or balcony.

#

As specified in CGA B149 Installation Codes. Note: Local codes or regulations may
require different clearances.

*

30” minimum for vinyl clad soffits

**

A vent must not terminate directly above a sidewalk or paved driveway, which is
located between two single-family dwellings and serves both dwellings.

***

Only permitted if veranda, porch, deck, or balcony is fully open on a minimum of 2
sides beneath the floor.