1 power connections, If the nmea 2000, Through the nmea 2000 – Maretron SSC200 User Manual

Page 12: Network connection, Ssc200 user’s manual, Page 8 revision 1.8

Advertising
background image

SSC200 User’s Manual

Figure 6 – NMEA 0183 Connector Face Views

Connect the other end of the cable consisting of individual wires using recommended practices
for installing NMEA 0183 products. Please note that NMEA 0183 does not have a standard for
connectors and the customer/installer should contact the manufacturer of the equipment to
which the SSC200 is being connected for information on how to properly connect the device to
the SSC200. The individual wires found within the cable have the following color coding.

Wire Color

Name

Description

Gray

TXA

Transmit Differential Output A Signal

Brown

TXB

Transmit Differential Output B Signal

Blue

RXA

Receive Differential Input A Signal

White

RXB

Receive Differential Input B Signal

Figure 7 – NMEA 0183 Cable/Wire Color Coding

2.4.2.1 Power Connections

If the NMEA 2000

®

interface is connected, power is supplied to the SSC200 through the NMEA

2000

®

network connection.

If only the NMEA 0183 interface is used, power connections must be made via the NMEA
2000

®

/Power connector. Using the included Micro Field Attachable Connector (Female),

connect two power wires (not included) to pins 2 and 3 of the field attachable connector (only
the two power pins need be connected) as shown in Figure 4 on page 6, assemble the
connector per the instructions packaged with the connector, and screw the connector snugly
into the NMEA 2000

®

/Power connector on the SSC200, as shown in Figure 8 below.

Page 8

Revision 1.8

Advertising