Ssc200 user’s manual – Maretron SSC200 User Manual

Page 28

Advertising
background image

SSC200 User’s Manual

Page A2

Appendix A – NMEA 0183 Interfacing

Revision 1.8

D-I:

Null

TXT – Text Transmission
The SSC200 transmits various status messages using the text transmission sentence.

$IITXT,A,B,C,D*hh<CR><LF>
Field A: Always reads “01”

B: Always reads “01”

C: Message identifier (see following table)

D: Text string (see following table)

Message
Identifier

Text String

Description

01 Deviation

Calibration

Started

This message is transmitted at the beginning of the magnetic deviation
calibration process.

02 Deviation

Calibration

Completed Successfully

This message is transmitted upon successful completion of the magnetic
deviation calibration process (i.e., a new deviation table has been stored
in permanent memory).

03 Deviation

Calibration

Failed to Complete

The SSC200 attempts to perform calibration 5 times before giving up and
issuing this sentence. Each time the SSC200 encounters an error (see
message identifiers 04, 05, and 06) it restarts the calibration process.
Upon the 5

th

error, the SSC200 exits the calibration routine and it must

be restarted before it will once again try to perform deviation calibration.

04 Deviation

Calibration

Turning Too Fast

During calibration, the vessel must not turn to fast where the SSC200 is
unable to reliably develop deviation data. If the SSC200 senses the
vessel turning to quickly, it will issue this message and restart deviation
calibration as long as it has not failed five times.

05 Deviation

Calibration

Turning Too Slow

During calibration, the vessel must not turn to slowly where the SSC200
is unable to reliably develop deviation data. If the SSC200 senses the
vessel turning to slowly, it will issue this message and restart deviation
calibration as long as it has not failed five times.

06 Deviation

Calibration

Invalid Movement

During calibration, the vessel must not jerk or reverse directions where
the SSC200 is unable to reliably develop deviation data. If the SSC200
senses an invalid movement, it will issue this message and restart
deviation calibration as long as it has not failed five times.

95

Serial Number: xxxxxxx

The SSC200 transmits this sentence once after it is powered up to
indicate its serial number.

96

Baud Rate: 4800

The SSC200 transmits this sentence once after it is powered up to
indicate its baud rate.

97

SW Version: 1.2

The SSC200 transmits this sentence once after it is powered up to
indicate its software version.

98

Model Version: 1.0

The SSC200 transmits this sentence once after it is powered up to
indicate its model version.

99

Model ID: SSC200

The SSC200 transmits this sentence once after it is powered up to
indicate its model identification.