Table b-12 pll characteristics – Motorola MC9S12GC-Family User Manual

Page 115

Advertising
background image

Device User Guide — 9S12C128DGV1/D V01.05

115

This is very important to notice with respect to timers, serial modules where a pre-scaler will eliminate the
effect of the jitter to a large extent.

Table B-12 PLL Characteristics

Conditions are shown in Table A-4 unless otherwise noted

Num C

Rating

Symbol

Min

Typ

Max

Unit

1

P Self Clock Mode frequency

f

SCM

1

5.5

MHz

2

D VCO locking range

f

VCO

8

50

MHz

3

D

Lock Detector transition from Acquisition to Tracking
mode

|∆

trk

|

3

4

%

1

NOTES

:

1. % deviation from target frequency

4

D Lock Detection

|∆

Lock

|

0

1.5

%

(1)

5

D Un-Lock Detection

|∆

unl

|

0.5

2.5

%

(1)

6

D

Lock Detector transition from Tracking to Acquisition
mode

|∆

unt

|

6

8

%

(1)

7

C PLLON Total Stabilization delay (Auto Mode)

2

2. f

OSC

= 4MHz, f

BUS

= 25MHz equivalent f

VCO

= 50MHz: REFDV = #$03, SYNR = #$018, Cs = 4.7nF, Cp = 470pF, Rs =

10K

.

t

stab

0.5

ms

8

D PLLON Acquisition mode stabilization delay

(2)

t

acq

0.3

ms

9

D PLLON Tracking mode stabilization delay

(2)

t

al

0.2

ms

10

D Fitting parameter VCO loop gain

K

1

-100

MHz/V

11

D Fitting parameter VCO loop frequency

f

1

60

MHz

12

D Charge pump current acquisition mode

| i

ch

|

38.5

µ

A

13

D Charge pump current tracking mode

| i

ch

|

3.5

µ

A

14

C Jitter fit parameter 1

(2)

j

1

1.1

%

15

C Jitter fit parameter 2

(2)

j

2

0.13

%

Advertising