INSTALLATION AND BREAK-IN PROCEDURES

9

OWNERS MANUAL

MAKITA - MAC700 / MAC2400 / MAC5200

DESCRIPTION OF OPERATION ... Continued

INSTALLATION AND BREAK-IN PROCEDURES

PRESSURE SWITCH UNLOADING VALVE: The pressure switch unloading valve located on
the side of the pressure switch, is designed to automatically release compressed air from the
compressor head and the outlet tube when the air compressor reaches “cut-out” pressure.

PRESSURE SWITCH: The pressure switch automatically starts the motor when the air tank
pressure drops to the factory set “cut-in” pressure. It stops the motor when the air tank pressure
reaches the factory set “cut-out” pressure.

SAFETY VALVE: If the pressure switch does not shut off the air compressor at its “cut-out”
pressure setting, the safety valve will protect against high pressure by “popping out” at its factory
set pressure (slightly higher than the pressure switch “cut-out” setting).

OUTLET PRESSURE GAUGE: The outlet pressure gauge indicates the air pressure available at
the outlet side of the regulator. This pressure is controlled by the regulator and is always less or
equal to the tank pressure. See “Operating Procedures”.

TANK PRESSURE GAUGE: The tank pressure gauge indicates the air pressure in the tank.

REGULATOR: The air pressure coming from the air tank is controlled by the regulator knob.
Turn the knob clockwise to increase pressure and counter-clockwise to decrease pressure. To
avoid minor re-adjustment after making a change in pressure setting, always approach the
desired pressure from a lower pressure. When reducing from a higher to a lower setting, first
reduce to some pressure less than desired pressure. Depending on the air requirements of each
particular accessory, the outlet regulated air pressure may have to be adjusted while you are
operating the accessory.

LOCATION OF THE AIR COMPRESSOR:

Locate the air compressor in a clean, dry and well-ventilated area. The air filter must be kept
clear of obstructions, which could reduce air delivery of the air compressor. The air compressor
should be located at least 12 inches away from the wall or other obstructions that will interfere
with the flow of air. The air compressor head and shroud are designed to allow for proper
cooling. If humidity is high, an air filter can be installed on the air outlet adapter to remove
excessive moisture. Follow the instructions packaged with the air filter for proper installation.

LUBRICATION AND OIL:

CAUTION: Do not attempt to operate this air compressor without first adding oil to the
crankcase. Serious damage will result from even limited operation unless filled with oil and
broken in correctly. Make sure to closely follow initial start-up procedures. Compressor oil is
provided; on a level surface, please fill the crankcase to proper level indicated on the sight glass.

WARNING: Compressors are shipped without oil. A small amount of oil may be present in the
pump upon receipt of the air compressor. This is due to factory testing and does not mean the
pump contains oil.