Ptc/phc – Motion 42-02-S028 User Manual

Page 13

Advertising
background image

Communication Connections

7

PTC/PHC

1. Connect the external Ethernet cable to Ethernet Port A on the USN-BASE assembly.
2. The boards in the controller are connected along a ribbon cable bus. Connect the M2C

assembly’s “From PCA” (JP3) to the last controller board on the bus using supplied rib-
bon cable.

3. Connect the M2C assembly’s CAN2 port to the “Internal Network” (J5) connector on the

USN-BASE assembly using the C-RJ-11 cable .

4. For Duplex, connect both CAN2 ports on the M2C assembly to supplied splitter. Then

plug the splitter into “Internal Network” (J5) connector on USN-BASE assembly.

5. Press RSTA to reset the USN board so that it will read its new connections.

6. With the Function Switch F8 switch UP (all others down), press N to cycle through the

menu to verify that information is correct.

• MC-USN version
• iReport version
• Number of cars connected
• Number of cars
• Number of floors

The controller is now ready to communicate.

The last board on the
ribbon cable bus will
have an empty socket.

Make the connection
from this socket.