Mc usn information, Jumper settings, Diagnostic leds – Motion 42-02-S028 User Manual

Page 15: Jumper settings diagnostic leds

Advertising
background image

MC USN Information

9

MC USN Information

This section describes the features of the USN device.

Jumper Settings

These jumper settings apply to the Rev X3-0 version of the MPU-M board.

• JP1 = A (5V)
• JP2 = Off
• JP3 = ON
• JP4 = Off
• JP5 = A (NORM)
• JP6 = Off
• JP7 = Off

Diagnostic LEDs

The diagnostic leds on the USN board show the health of the system at a glance. The USN
board is used in several MCE product lines and is permanently labeled according to its primary
application. Disregard the LED labels on the board. Instead, refer to the following illustration:

Client Connected

Client Connected

Client Connected

Client Connected

Client Connected

Client Connected

At least one device connected

Receiving data from Internal Network connector (PTC/PHC)

Receiving data from External Network connector (Escalator)

Receiving data from RS-232B connector (IMC)

Main software loop light

500msec toggle light