Acceptance and routing, First things first, Testing for acceptance – Mars CASHFLOW 126 User Manual

Page 14: Coin routing

Advertising
background image

ACCEPTANCE AND ROUTING

When the product is successfully mounted you will need to confirm that it is set up

correctly to accept good coins/tokens and direct them to where you want them to go.

First things first

q

Press and release the reject button on the machine. Confirm that the lid on the

front of the validator closes fully when the reject button is released. If it does not

close fully the validator cannot function properly.

q

Test that power is on by checking that the green LED on the front of the validator is

illuminated, it will flash off once when the reject lever is pressed.

Testing for Acceptance

q

Insert into the machine a selection of all the coins/tokens shown on the validator

label. Acceptance of each one will be indicated by the LED flashing off once, and if

the coin/token is outside of the programmed window it will flash off twice. If the

LED flashes three time this indicates that the coin/token has been rejected by the

validator 4th sensor. Should the LED flash off four times this indicates either a

hardware or software inhibit is being applied.

Coin Routing

q

Confirm that all coins and tokens are being routed to the required exits. If they are

not refer to the Trouble Shooting section. Settings may have been made on the

machine for hopper or tube limit switches, and these must be taken into account.

q

If further help is required then consult the Operators Handbook for the product or

contact either your distributor or local MEI office.

10

©, Mars, Inc., 1998

CashFlow

®

126 and CashFlow

®

129 selectors User Guide

Advertising