Product Configuration - teaching a new token,
channel 1

Example:- To Teach a Token (with standard window limits) into channel
1 follow these simple steps.

1.

Switch Validator Power OFF.

2.

Set 4 Way switches to Token Teach.

3.

Set Rotary Switch Dial to position F ((standard
window limits). ).
(Position E will teach narrow slug windows)

4.

Switch Validator Power ON (LED will Flash).

5.

Drop between 10 and 20 Tokens.

6.

Return switches to Normal Operation. (LED
should stop flashing and stay on to indicate a
successful change). If the LED continues to
flash this indicates a failure to teach the token.
If needed repeat the process from step 1.

7.

Token successfully taught & programmed
into Channel 1.

20

©, Mars, Inc., 1998

CashFlow

®

126 and CashFlow

®

129 selectors User Guide

Set switches 2, 3 and 4
as shown here.

Channel Enable

ON

1

2

3

4

LED Flash Codes for Tokens:

2 flashes = No activity detected (for last 30 seconds)

3 flashes = Insufficient Tokens (10 min.)

4 flashes = Invalid Rotary Switch (setting E or F)

6 flashes = Token diameter outside allowable limits

5 flashes = Token thickness outside allowable limits

7 or 8 flashes = Token material outside allowable limits