background image

Product Configuration - teaching a new token,
channel 0

Example:- To Teach a Token (with standard window limits) into channel
0 follow these simple steps.

1.

Switch Validator Power OFF.

2.

Set 4 Way switches to Token Teach.

3.

Set Rotary Switch Dial to position F (standard
window limits).
(Position E will teach tight token window limits)

4.

Switch Validator Power ON (LED will Flash).

+5.

Drop between 10 and 20 Tokens.

6.

Return switches to Normal Operation. (LED
should stop flashing and stay on to indicate a
successful change). If the LED continues to
flash this indicates a failure to teach the token.
If needed repeat the process from step 1.

7.

Token successfully taught & programmed
into Channel 0.

©, Mars, Inc., 1998

19

CashFlow

®

126 and CashFlow

®

129 selectors User Guide

Set switches 2, 3 and 4
as shown here.

Channel Enable

ON

1

2

3

4

LED Flash Codes for Tokens:

2 flashes = No activity detected (for last 30 seconds)

3 flashes = Insufficient Tokens (10 min.)

4 flashes = Invalid Rotary Switch (setting E or F)

6 flashes = Token diameter outside allowable limits

5 flashes = Token thickness outside allowable limits

7 or 8 flashes = Token material outside allowable limits