SETUP FOR OPERATION

1. Before powering or starting, check for damage that could prevent this

equipment from proper operation or performing it’s intended function. Check
for binding and alignment of moving parts. Check for damaged, broken, or missing
parts.
2. Verify the On/Off switch is in the OFF position.
3. Before connecting the MK-370EXP to a power supply, be sure the voltage,
cycle and phase of the job site power source meet the requirements of TABLE 3
4. Use an approved Ground Fault Circuit Interrupter (GFCI)
5. Do not cover the motor vents as this could lead to motor overheating.

VOLTAGE

115v

CYCLE

60Hz

PHASE

1-phase

Table 3

1. In order to avoid breaker tripping, a 20 amp circuit breaker should be used.
2. If using an extension power cord, make sure the length and wire gauge correspond to the
requirements listed in TABLE 1 on page 10. An extension power cord that is too small in
wire gauge (diameter), or too long in length, will cause the motor to overheat and could

cause premature failure.

NOTE:

(A)

Ensure the ON/OFF Switch

is in the OFF position

(C)

Plug the GFCI into the

Power source

(B)

Plug MK-370EXP into the

GFCI

GFCI

CAUTION

MK-370EXP

SETUP