MK Diamond Products MK-370EXP User Manual

Page 40

Advertising
background image

GFCI

40

“Rodding" cooling channels is performed by inserting a small wire rod through the cooling inlet
on top of the Blade Guard and directing the rod out through each of the cooling flow tubes
located on the underside of the Blade Guard. The cooling channels should be “rodded" until all
ports are free of foreign debris.

NOTE:

(K)

Rod Cooling Channels and

recheck flow

BLADE STOPS TURNING

(B)

Check to see if the Ground

Fault Circuit Interrupter

(GFCI) is tripped

(A)

Verify all plugs are fully

installed

(C)

Verify circuit breaker at least

20 amps – if not, move to

20 amp circuit

(E)

Check power source voltage

is 115v – if not 115v, move to

another circuit

(D)

Verify circuit breaker not

tripped. If tripped, reset

once

MK-370EXP

MAINTENANCE & TROUBLESHOOTING