a)

Pins 1,14,2,15,3,16,4,17 connects to alarm input: ALARM1~ALARM8

b)

Pins 5 & 18 = OUTPUT Relay 1 - 6 & 19 = OUTPUT Relay 2 Each Relay (normally open):

c)

Pins 7&20 = OUTPUT 3 is a controllable +12V output.

d)

Pins 8, 9 & 21 are +12V power output, Use for Low current items only such as Relays and Alarm Devices.

e)

Pins 10 & 22 are the B line of RS485, Pins 11 & 23 are the A line of RS485;

f)

Pins 12, 13, 24 & 25 are Ground (Gnd).

Combined as RS485 B line

Combined as RS485 A line

Decoder

Decoder

A B

A B

Alarm input ALARM 1

ALARM 8

Alarm output

ALARMOUT1

ALARMOUT2

Controllable +12V output

+12V output

Gnd

120 End of Line

(EOL)

resister

required.