Section 4 − operation, 1. controls, 2. mig mode – Miller Electric MILLERMATIC 350P User Manual

Page 30: 3. jog mode

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-1327 Page 26

SECTION 4 − OPERATION

4-1. Controls

1

Pulse Indicator Light

.

Pulse only lights if unit has the pulse
MIG module and is programmed for

pulse MIG.

2

MIG Indicator Lights

Pulse (1) and MIG (2) illuminate to Indicate

weld mode of unit.
3

Process Light

PROCESS illuminates when unit is in

Process select menu.
4

Wire Light

WIRE illuminates when unit is in Pulse MIG

program select menu.
5

Timers Light

TIMERS illuminates when unit is in Timers

menu.
6

Setup Button

Use button to access Timers, Process and

Wire menus.

7

Arc Control Button

Use button to select either inductance

control in MIG welding mode or Sharp Arc

in Pulse MIG welding mode.

8

Left Knob

Use knob to adjust volts in MIG welding

mode or change parameter values in

Setup.

9

Right Knob

Use knob to adjust wire speed in MIG

welding mode or change parameter values

in Setup.

10 Left Display
11 Right Display

12 Weld Functions/Setup Indicator

Lights

VOLTS illuminates in MIG welding mode

indicating volts in left display can be

adjusted. Also, VOLTS lights to indicate left

display is showing actual voltage during

welding and for 5 seconds after the arc is

extinguished.
ARC LENGTH illuminates in Pulse MIG

welding mode indicating Arc Length can be

adjusted.
SETUP illuminates when a parameter on

the corresponding display above the light

can be adjusted.
WIRE SPEED illuminates in either Pulse

MIG or MIG welding mode indicating wire

speed can be adjusted.
AMPS illuminates indicating welding amps

appears in the display, instead of wire

speed, during welding and for 5 seconds

after the arc is extinguished.

1

11

Ref. 213 935-A

9

8

6

5

4

3

10

12

7

2

.

The first time the welding power source is energized it starts in MIG welding mode. Each time after the initial startup, when the unit is turned off,
whatever mode and parameter settings were last set will remain as the current settings the next time the unit is energized.

4-2. MIG Mode

In MIG mode, VOLTS is lit under left display and WIRE SPEED is lit under right display. Left knob is used to adjust

welding voltage within a range of 10-32 volts, and right knob is used to adjust wire feed speed within a range of 25-700

IPM. Refer to weld chart in front compartment for proper parameter settings according to wire type, shielding gas, and

material type and thickness.

4-3. Jog Mode

If gun trigger is pressed and held for more than 3 seconds without striking an arc, unit will automatically shut off weld

power. For MIG guns, shielding gas will shut off after 1 minute, and for spool guns, shielding gas will continue to flow