Mr. Heater MHVFB10LP User Manual

Page 11

Advertising
background image

11

Installation Instructions and Owner’s Manual

Unvented LP-Gas Fired Buddy Wall-Mount Heater

Make sure grille guard is in place before running

heater. If screen or grille guard is removed for servic-

ing it must be replaced prior to operating the heater.

WARNING: Failure to keep the primary air

opening(s) of the burner(s) clean may result in soot-

ing and property damage.

CLEANING ODS/PILOT AND BURNER

Use as vacuum cleaner, pressurized air or

small soft bristled brush to clean.

CLEANING BURNER PILOT AIR HOLE INLET

We recommend that you clean the unit ever 2,500

hours of operation or every three months. We also

recommend that you keep the burner tube and pilot as-

sembly clean and free of dust and dirt. To clean these

parts we recommend using compressed air no greater

than 30 psig.
This can be done by using a vacuum cleaner in the

blow position, using compressed air in a can, please

follow the directions on the can. If you don’t follow

directions on the can you could damage the burner or

pilot assembly. In addition, the directions that follow

should also be followed.

1. Shut off the unit, including the pilot. Allow the

unit to cool for at least thirty minutes.

2. Inspect burner and pilot for dust and dirt.
3. Blow air through the port/slots and holes in the

burner.

A yellow tip on the pilot flame indicates dust and dirt

in the pilot assembly. To clean the pilot assembly find

the small pilot air inlet hole about two inches from

where the pilot flame comes out of the pilot assembly

(see Pilot Air Inlet Hole in figure 25). With the unit off,

lightly blow air through the air inlet hole. You may blow

through a drinking straw if compressed air is not avail-

able.

Figure 25

CLEANING HEATER CABINET

Air passageways

Use a vacuum cleaner or pressurized air to

clean exterior

Use a soft cloth dampened with a mild soap

and water mixture. Wipe the cabinet to remove

dust.

SPECIFICATIONS

MHVFB10LP

BTU (Available)

10,000

Type of Gas

LP-Gas Only

Ignition

Piezo

Pressure Regulator Setting

10 Inches of

Water

Inlet Gas Pressure (Maximum) 14 Inches of

Water

Inlet Gas Pressure (Minimum) 11 Inches of

Water

Burners / Orifice nozzles

1

Thermostatic Control

No

Clearances: inches (mm)

Top

36” (915cm)

Sides

6” (152cm)

Floor (min. to top of carpet)

2” (51cm)

Fabric / flammable objects

36” (915cm)

Advertising