replaced prior to operating the heater.

OBSERVED SYMPTOM

POSSIBLE CAUSE

REMEDY

1. Ignitor electrode positioned wrong.
2. Ignitor electrode is broken.
3. Ignitor electrode not connected to ignitor.
4. Ignitor cable pinched or wet.

5. Broken ignitor cable.
6. Bad Piezo ignitor.

1. Gas supply turned off or equipment shut-

off valve closed.

2. Air in gas line when installed.

3. ODS/pilot is clogged.

4. Gas regulator setting is not correct
5. Control knob not in pilot position
1. Control knob not fully pressed in.
2. Control knob not pressed in long enough

3. Equipment shutoff valve not fully open
4. Thermocouple connection loose at con-

trol valve

5. Pilot flame not touching thermocouple,

which allows thermocouple to cool, caus-

ing pilot flame to go out. This problem

could be caused by one or both of the

following:
a. Low gas pressure
b. Dirty or partially clogged ODS/pilot

6. Thermocouple damaged
7. Control valve damaged
1. Burner orifice is clogged

2. Burner orifice diameter to small
3. Inlet gas pressure is too low
1. Manifold pressure is too low
2. Burner orifice is clogged

When Piezo ignitor knob is

turned, there is no spark at pilot

ODS/pilot lights but flame

goes out when control knob is

released

When Piezo ignitor knob is

turned, there is a spark at the

ODS/pilot but no ignition

Burner does not light after

ODS/pilot is lit

1. Reposition electrode
2. Replace electrode
3. Reconnect ignitor cable
4. Free ignitor cable if pinched by any metal

or tubing. Keep ignitor cable dry.

5. Replace ignitor cable
6. Replace control valve (Piezo is part of

control valve on 10K units).

1. Turn on gas supply or open equipment

shutoff valve.

2. Continue holding down control knob. Re-

peat ignition operation until air is removed.

3. Clean ODS/pilot (see Cleaning and Main-

tenance page 13).

4. Replace gas regulator
5. Turn Control knob to pilot position
1. Press in control knob fully
2. After ODS/pilot lights, keep control knob

pressed in for 30 seconds

3. Fully open equipment shutoff valve
4. Hand tighten thermocouple nut until snug,

and then tighten 1/4 turn more.

5. -

a. Contact local gas company
b. Clean ODS/pilot (see Cleaning and

Maintenance, page 13).

6. Replace thermocouple
7. Replace Control valve.
1. Clean burner orifice (see Cleaning and

Maintenance on page 13), or replace

burner orifice

2. Replace burner orifice
3. Contact local gas company
1. Contact local gas company
2. Clean burner orifice (see Cleaning and

Maintenance on page 13), or replace

burner orifice

Delayed ignition of burner