Minicom Advanced Systems DX User IP User Manual

Page 49

Advertising
background image

USER GUIDE

48

From the DX User IP Menu choose IPMI Settings. The IPMI Settings appears. See
Figure 37.

Figure 37 IPMI Settings

IPMI disabled - Disables IPMI. Status via IPMI and Event Log via IPMI are not
available and the power on/off and reset functions won't use IPMI.

BMC address - Hexadecimal Baseboard Management Controller address. Needed
for all types of communication to the IPMI-interface. Usually you can find this
address in the BIOS of the host system. The default and common value is 20.

IPMI over Serial - If your host system supports IPMI V1.5 and has an Intel EMP
(Emergency Management Port, usually COM2) connector, you can connect IPMI
through serial port 1 on DX User IP. Please note:

·

Set the EMP port to Always enable and switch off the Restricted Mode.

·

The BMC should accept a null username and a non-null password account

as login.

·

Passwords are 4 -16 characters long.

·

Use a null modem cable for connection

IPMI over LAN - You can connect the IPMI over a LAN connection. You need a
host system with IPMI V1.5 and a network adapter with a sideband connection to
the BMC (mostly on board). In the IPMI Settings, enter the IP-address of this host
system and the correct password for the LAN connection.

You can also access other IPMI systems when you enter their IP address.

Advertising