Cuestation log window messages – Meyer Sound Matrix3 LX-300 User Manual

Page 45

Advertising
background image

Repeated occurrence of an error indicates a fault with the associated expansion module ("DMA0" corresponds to
an Analog Audio Input module; "DMA1" to a CobraNet module).

CueStation Log Window Messages

CueStation's Log window reports a number of errors from the Matrix3 system. These can be helpful in diagnosing
the root cause of a failure. The messages relevant to booting an LX-300 are:

Explanation

Error Code

No Flash program detected.

M3 E1.5.0, Built on yy/mm/dd, at hh:mm:ss

 

DMEM memory usage exceeded.

Matrix exceeds DSP capacity.

Total Dynamix points exceeded x

ADSIR_InterruptsHaveBackedUp

DSP Usage has reached limit. Halting processing. Please
re-send configuration.

ADSIR_BadSampleDetected

Corrupt audio detected. Muting audio for 1 second.

 

Unmuting audio.

INITMAIN_HSB_Packet_Error

HSB Packet error detected

Flash program memory error

FLASH ReadFile got wrong CRC for file x, wanted y, got
z

 

FLASH ReadRawFile got wrong CRC for file x, wanted
y, got z

Various FPGA programming errors

FPGA still not done after 4mSeconds waiting

 

FPGA Length Mis-Match

 

FPGA program error. Byte x, bit x TotalBits x

 

FPGA 'DONE' not active at end of write.

Various EtherTracks Errors

ETRX: Cannot allocate memory

 

ETRX: Cannot read et_boot.bin (x)

 

ETRX: Corrupted DualPort->HSB transfer. [0x]=0x, should
be 0x

 

Read Again: [0x]=0x, should be 0x

 

ETRX: Could not read et_linux.bin (x, 0x) Trying a second
time

 

ETRX: CRC failed. ET=0x Should be=0x. #P=x LAST[0x]

 

ETRX: # Packets not right. ET=0x Should be=0x. #P=x
LAST[0x]