3. engine prestart checks (kohler-powered units) – Miller Electric 280 NT User Manual
Page 19
OM-4402 Page 15
4-3. Engine Prestart Checks (Kohler-Powered Units)
801 221 / 802 692
1/2 in
(13 mm)
Full
Gasoline
Full
Check all fluids daily. Engine must be
cold and on a level surface. Unit is
shipped with 10W30 engine oil.
.
Follow run-in procedure in engine
manual.
.
This unit has a low oil pressure
shutdown switch. However, some
conditions may cause engine
damage before the engine shuts
down. Check oil level often and do
not use the oil pressure shutdown
system to monitor oil level.
Fuel
Add fresh fuel before starting engine
the first time (see maintenance label for
specifications). Fill fuel tank up to 1/2
in. (13 mm) from top to allow room for
expansion. Check fuel level on a cold
engine before use each day.
Oil
After fueling, check oil with unit on level
surface. If oil is not up to full mark on
dipstick, add oil (see maintenance la-
bel).
.
To improve cold weather starting:
Keep battery in good condition.
Store battery in warm area off con-
crete surface.
Use correct grade oil for cold
weather.