4-3. Engine Prestart Checks (Kohler-Powered Units)

801 221 / 802 692

1/2 in

(13 mm)

Full

Gasoline

Full

Check all fluids daily. Engine must be

cold and on a level surface. Unit is

shipped with 10W30 engine oil.

.

Follow run-in procedure in engine
manual.

.

This unit has a low oil pressure
shutdown switch. However, some
conditions may cause engine
damage before the engine shuts
down. Check oil level often and do
not use the oil pressure shutdown
system to monitor oil level.

Fuel
Add fresh fuel before starting engine

the first time (see maintenance label for

specifications). Fill fuel tank up to 1/2

in. (13 mm) from top to allow room for

expansion. Check fuel level on a cold

engine before use each day.
Oil
After fueling, check oil with unit on level

surface. If oil is not up to full mark on

dipstick, add oil (see maintenance la-

bel).

.

To improve cold weather starting:

Keep battery in good condition.
Store battery in warm area off con-
crete surface.

Use correct grade oil for cold
weather.