SECTION 11 − AUXILIARY POWER GUIDELINES

11-1. Selecting Equipment

aux_pwr 4/01 − Ref. ST-159 730 / ST-800 577

1

Auxiliary Power Receptacles

− Neutral Bonded To Frame

2

3-Prong Plug From Case

Grounded Equipment

3

2-Prong Plug From Double

Insulated Equipment

OR

2

Be sure equipment
has this symbol
and/or wording.

3

1

11-2. Grounding Generator To Truck Or Trailer Frame

S-0854

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding

Terminal

4

Grounding Cable

Use #10 AWG or larger insulated

copper wire.
Y If unit does not have GFCI re-

ceptacles, use GFCI-pro-

tected extension cord.

OR

1

2

Electrically bond generator
frame to vehicle frame by
metal-to-metal contact.

GND/PE