Operating procedures, Starting the engine, Caution – Makita G12010R User Manual

Page 22

Advertising
background image

(1) Make sure that the no-fuse breaker is

off.

(2) Turn the fuel cock to the vertical

(open) position

(3) Turn the key switch to the

"

START

"

position.
If the engine won't start, turn the
switch back to

"RUN"

position and then

wait for approximately 10 seconds to
try it again.

NOTE :

You might have to keep the starter
running for at least 3 to 5 seconds,
since the engine incorporates the
mechanism in it where the ignition
circuit is activated by the increase of
hydraulic pressure.

In the following occasion, two or three
trials may be required for starting the
engine :

(1) The very first starting of a new

generator.

(2) After the refueling of the engine

which has been stopped due to fuel
shortage.

(3) Starting after the oil filter change.

(4) Warm the engine up for a minute or

two. Longer time would be needed
in cold weather.

START

RUN

START

STOP

RUN

STOP

11

5. OPERATING PROCEDURES

STARTING THE ENGINE

CLOSE

CLOSE

OPEN

Check the oil level before each operations. (See page 6)

Perform the specified Daily Inspection to see if it is in normal condition.

CAUTION

ON

OFF