(1) AC APPLICATION

(a) Ground the generator, using the

ground terminal located at the side of
the panel.

(b) Before starting the engine, check that

the no-fuse breaker of the generator
and the power switches of the
appliances are turned off.

(c) Connect the plugs of the appliances to

the receptacles before starting the
engine. If you wish to use for a long
period of time, connecting to the output
terminal is recommended.

(d) Start the engine and check that the

voltage meter is indicating correct
voltage.

ON

OFF

Grounding spike