14

up to 30A

up to 30A

up to 20A

NEMA

5-20R

NEMA

L5-30R

NEMA

L14-30R

NEMA

5-20P

NEMA

L5-30P

NEMA

L14-30P

GFCI (Ground Fault
Circuit Interrupter)
Receptacle, duplex

(REC1)

Locking Receptacle
(REC2)

Locking Receptacle
(REC3)

Style

Ampere

Receptacle

AC plug

Description

up to 50A

Locking Receptacle
(REC4)

TABLE 1

Check the amperage of the receptacles used referring to TABLE 1, and be
sure not to take a current exceeding the specified amperage.

Be sure that the total wattage of all appliances dose not exceed the rated
output of the generator.

To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn
it clockwise to the lock position.

Be sure to ground the generator if
the connected electrical device Is
grounded.

WARNING

TWIST

NOTE :

When the no-fuse breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
Makita dealer or service shop.