29

CHECKING CARBON BRUSH

If the brush become excessively worn, its
contact pressure with the slip ring
changes and causes a roughened surface
on the slip ring, resulting in irregular
generator performance.

Check the brush every 500 hours or if
generator performance is irregular.

If the brush is 0.2 in.(5 mm) long or less,
replace it with a new one.

(a) Remove the brush cover.

(b) Disconnect the wire connector and

remove the brush.

(c) Carefully note the brush direction and

relative position with the slip ring when
installing new brush.

15 to 5 mm

(0.6" to 0.2")

BRUSH

BRUSH
HOLDER

BRUSH
COVER

BRUSH
HOLDER

FLANGE
BOLT

SCREW